Tesla Wall Connector 22kW EV Charger Installation with Creos R2 Automation in Hagen (Steinfort), Luxembourg
EV Charger
Completed
SPARK-EV-2026-009

Tesla Wall Connector 22kW EV Charger Installation with Creos R2 Automation in Hagen (Steinfort), Luxembourg

Location

Hagen, Steinfort (L-8365), Luxembourg

Date

20 November 2026

Client

Andrius Sujeta — Hagen (L-8365, Steinfort)

Features

Tesla Wall Connector (Up to 22 kW 3-Phase / 71 km Range per Hour) 7.3m Integrated Type 2 Cable & Wi-Fi App Control 15m NYY-J 5x4mm² Black 3-Phase Supply Cable Galvanized Steel Vertical Riser & Metal Cable Raceway 4-Pole 40A 30mA Differential RCD & 3-Pole 16A/20A Safety Breaker Creos R2 Automation (Eaton Z-SCH230/63-04 + FAZ-C2/1) Creos Smarty T210-D R2 Bus Connector Full Creos & Klimabonus Government Subsidy Documentation

Project Description

⚡ Executive Summary — Key Project Takeaways (Hagen / Steinfort L-8365)

  • Project Reference & Location: SPARK-EV-2026-008 (Invoice 2026-047) — Underground residential parking bay (#1-2) at Rue Principale, L-8365 Hagen (Commune of Steinfort), Luxembourg.
  • EV Charging Hardware: Tesla Wall Connector Gen 3 (3-phase up to 22 kW / 71 km of range per hour, 7.3-meter Type 2 cable, Wi-Fi OTA updates, Tesla app scheduling, compatible with all Type 2 EVs and PHEVs).
  • 15m 3-Phase Power Feeder & Armor: 15 meters of heavy-duty NYY-J 5×4 mm² black copper cable protected inside a vertical galvanized steel riser shroud and horizontal metal cable tray.
  • Switchboard Protection & Creos R2 Automation: Dedicated 4-pole 40A 30mA differential RCD (FI switch), 3-pole 16A/20A safety circuit breaker, Eaton Z-SCH230/63-04 (25A, 230V AC, 4 NC, 3TE) installation relay, and Eaton FAZ-C2/1 (1P 2A C-curve, 15 kA) control breaker wired directly to the Creos Smarty (Sagemcom T210-D) R2 bus connector.
  • Turnkey Administration: Complete Creos Luxembourg technical declaration and Government Klimabonus subsidy dossier included at €0 surcharge.

Project Overview: Tesla Wall Connector Installation in Hagen (Commune of Steinfort)

Our residential client Andrius Sujeta in Hagen (L-8365, Commune of Steinfort), Luxembourg commissioned SparkSonic SARLS for a turnkey electric vehicle charging station (installation borne de recharge en copropriété) at underground parking space #1-2. The installation required routing a dedicated 3-phase feeder from his individual Creos Smarty T210-D smart meter in the communal electrical room to the underground parking bay while meeting 100% of TAB Creos Luxembourg R2 load-management and syndic fire-safety standards.

Complete Hardware & Electrical Bill of Materials (Invoice 2026-047)

System Subsystem Installed Component & Technical Specification Qty Compliance & Performance Role
EV Charging Station Tesla Wall Connector Gen 3 (TPN 1529455-42-J) — Up to 22 kW 3-Phase (up to 71 km range/hr), 7.3 m Type 2 Cable, Wi-Fi & Tesla App Control, IP55 1 unit Universal Type 2 smart charging with one-touch Tesla charge-port opening
3-Phase Power Cable NYY-J 5×4 mm² Black Copper Cable + Galvanized Steel Vertical Protection Riser, Metal Raceway, Pipes & Clamps 15 m Low voltage drop & heavy mechanical impact protection in shared parking
Differential & Overcurrent 4-Pole 40A 30mA Differential Circuit Breaker (FI Switch) + 3-Pole 16A/20A B-Curve Safety Breaker 1 set Dedicated human-touch earth-leakage & 3-phase short-circuit protection
Creos R2 Automation Kit Eaton Z-SCH230/63-04 (Z-SCH230/25-04) Contactor (25A, 230V AC, 4 NC / 4 Öffner, 3TE) + Eaton FAZ-C2/1 (1P 2A C-Curve, 15 kA) + Smarty T210-D Bus Connector & R2 Cable 1 set Mandatory Creos Luxembourg R2 remote grid load modulation
Subsidy & Grid Dossier Full Creos Technical Declaration & Luxembourg Government Subsidy (Klimabonus) Documentation Included Zero-hassle grid approval & state grant reimbursement support

🇫🇷 Résumé du Projet en Français (Installation Tesla Wall Connector à Hagen / Steinfort L-8365)

SparkSonic SARLS a réalisé l’installation clé en main d’une borne de recharge Tesla Wall Connector (jusqu’à 22 kW en triphasé, câble Type 2 de 7,3 m, Wi-Fi) dans un parking souterrain résidentiel à Hagen (L-8365, Commune de Steinfort), Luxembourg. L’installation comprend 15 mètres de câble NYY-J 5×4 mm² sous protection mécanique en acier galvanisé, un interrupteur différentiel tétrapolaire 40A 30mA, un disjoncteur tripolaire 16A/20A, ainsi que le kit complet d’automatisation Creos R2 (contacteur Eaton Z-SCH230/63-04 et disjoncteur Eaton FAZ-C2/1) raccordé directement au port R2 du compteur intelligent Creos Smarty (Sagemcom T210-D). Le dossier complet pour Creos et la subvention étatique Klimabonus a été inclus gratuitement.

Frequently Asked Questions — Tesla Wall Connector Installation in Steinfort & Luxembourg

Is the Tesla Wall Connector compatible with non-Tesla electric cars in Luxembourg?

Yes. The European Tesla Wall Connector uses a standard Type 2 (IEC 62196) plug and charges any Type 2 electric vehicle or plug-in hybrid (Tesla, BMW, VW, Audi, Mercedes, Hyundai, BYD, Renault, Peugeot, etc.) while offering smart scheduling and monitoring via the Tesla app.

Why is Creos R2 automation required for a Tesla Wall Connector in Hagen / Steinfort?

Network operator Creos Luxembourg requires residential charging stations to connect to the Smarty (Sagemcom T210-D) smart meter’s R2 port via an installation contactor (Eaton Z-SCH230) and control breaker (Eaton FAZ-C2/1) so the grid can safely modulate peak loads in compliance with TAB Creos.

Planning a Tesla Wall Connector or EV Charger in Steinfort or Anywhere in Luxembourg?

Speak directly with SparkSonic’s certified electricians for a fast site inspection, transparent quote, and full Creos & Klimabonus subsidy paperwork.

Project Gallery

Planning a Similar Project in Luxembourg?

Request your free quote and on-site technical assessment from our Creos-certified electrical & energy team.

🚨 24/7 Emergency / Dépannage
Call +352 661 315 657
📋 Free Quote
Devis Gratuit